Search our database for detailed information about our products and services. Hood lights the hood light fixtures must be kept dry. A hotel located in boston, ma with a four hood kitchen design with an exhaust fan for each hood totaling 10hp, with a 7. Melink intelli hood controls table of contents step installation contractor page 1 install io processor electrical 4 2 install electronic motor starter electrical 6 3 install keypad mechanical 8 4 install exhaust temperature sensor mechanical 9 5 install optic sensors mechanical. While creating and flourishing relationships with companies such as jll, cbre. Technote 21 demand controlled kitchen ventilation dckv. This code guide should be used for diagnosing ih2 fault codes. The melink intellihood uses both heat sensors and optic sensors to monitor the cooking operation and modulate the airflow. Product catalogs, warranty statements, and installation and operation manuals. It is strongly recommended that a design professional from melink corporation assist in the design and layout of the intelli hood controls and the calculation of the energy savings. Our dependable quality, reliable delivery and knowledgeable followup service has made price a market leader in supplying air distribution products and related equipment. You are now ready to program the intellihood controls using the setup switches on the keypad.
For new construction, the intellihood includes a variable frequency drive or vfd for each. That was the origin of the intelli hood, the first demand controlled kitchen ventilation, or dckv system, which the melink corp. Water inside a light fixture will create a short on the circuit and damage the melink processor which powers the lights. Water wash type external makeup air canopy for all types. Authored technical manuals with preventive maintenance components. Mitsubishi electric meldas c6 controller interface manual pdf. Honeywell c7027a1023 minipeeper uv sensor 12 mounting overview. Responsible for all intelli hood retrofit projects within corporate office, amusement, and restaurant verticals. Mitsubishi electric meldas c6 controller interface manual. We recently installed an ondemand kitchenventilation system, says stoughton. Feb 25, 2016 69 laboratories fume hood velocities 60 fpm allowable when a the reduction in face velocity is controlled by an automatic system which does not require manual intervention. Over the years, melink corp has designed and implemented three intellihood systems.
Bacnet protocol implementation conformance statement pics. For new construction, the intellihood includes a variable frequency drive or vfd for each kitchen exhaust and makeup air fan. The melink system also optimizes energy efficiency by determining the amount of exhaust air required to capture and contain effluent from the cookline, allowing exhaust system to run at lowest possible speed. Intellihood installation manual melink corporation. Therefore, you do not need a conventional magnetic motor starter with our system. Adam householder, leed ga program manager franklin. All wash components within the hood are complete and ready for connection to hot water, sanitary sewer.
Three exhaust fans 9 hp total serving the large hood in the campus dining main kitchen were retrofit with the melink intelli hood exhaust fan control system. Read all labels and follow the directions whenever working on the equipment. Xgh2o and melink intelli hood keypad ed o gh f faul hoo mel oe ee system components hood the hood is shipped from the factory prepiped and ready to install. Intellihood is set to appropriately send the exhaust fans to full speed based on conditions detected by temperature and optic sensors. The system utilizes variable speed drives on all exhaust and supply fans when a chef commences cooking and turns on a gas burner, the hood. Intellihood troubleshooting guide melink corporation 5 965 7300. C7027a1023 honeywell c7027a1023 minipeeper uv sensor. We offer technical data, application articles, project profiles, videos, industry articles, product literature, and more. Also indicates the type of fault for easy troubleshooting melink corporation 5. The melink system utilizes both temperature sensors mounted in the exhaust duct and optical sensors that pass a light beam across the hood opening to detect heat, steam or smoke from.
Adam householder, leed ga program manager franklin energy. Melink corporation vendor id 654 ecocanopy product name. The automatic system shall increase the airflow to the flow required by c1 when the hood is accessed. Led ceiling supply plenums conveyor refurbishing brochure. It the speed of the motors by varying the output frequency and voltage. Melink intelli hood installation manual installation manual 33 pages danfoss ecl comfort 310 operating manual operating manual 116 pages victron energy bluesolar manual manual 67 pages yokogawa ut52a technical information technical information 4 pages. Water wash type external makeup air canopy for all types of.
Cal poly san luis obispo, hvac demonstration projects. Cycle costing manual for the federal energy management program. Caddy corporation caddy corporation announces partnership. The electronic motor starter is a vfd that receives a startstop command and a 420ma signal from the io processor. Melink corporation 5 9657300 8 melink intellihood controls. All wash components within the hood are complete and ready for connection to hot water, sanitary sewer drain and the electrical sources. Help menu the help menu contains instructions for contacting technical support and other information. Danger, warning, caution and note paragraphs within this instruction manual the above paragraphs list some general safety reminders and safety recommendations to be followed when operating or installing this equipment. The policies below describe the practices greenheck follows to ensure compliance with these laws. We went with intelli hood from ohiobased melink corporation.
C7027a1023 honeywell c7027a1023 minipeeper uv sensor 1. You will find a large assortment of informational pieces to help guide you through your next building project. Melink intelli hood installation manual installation manual 33 pages danfoss ecl comfort 310 operating manual operating manual 116 pages victron energy bluesolar manual manual 67 pages. The melink intelli hood controls are an innovative solution to the typical kitchen ventilation system that operates at full capacity all day and sometimes all night long. High plume dilution laboratory exhaust fans greenheck. For more information about intellihood by melink corporation, please visit. While the smart hood has been a strong seller and a good solution for lower volume kitchens it is a temperature based only system and they have limitations.
Installation manual melink intellihood controls culinaire. Cal poly installed a melink intelli hood exhaust fan control system to correlate fan running times to stove use, decreasing fan energy use. Top of hood on top of the hood, one will find air purge units apu, temperature probes, and a network of control cables. Intellihood troubleshooting guide cemco electric, inc. We applied ecosense known as intelli hood in the us to the kitchen ventilation system to run fans only at the speed required to match cooking activity. Aux touchpad the aux touchpad at is a secondary user interface point of the intelli. Bacnet protocol implementation conformance statement. This is where melink and their intelli hood system enter the picture. National institute of standards and technology nist.
In most cases this will mean one temperature sensor per hood. Table of contents 2 step installation page 1 install io processor 4 2 install electronic motor starter 6 3 install keypad 8 4 install exhaust temperature sensor 9 5. Intellihood controls melink setup 7 keypad startup 1 press 100% switch press the 100% reset switch to operate the fans at full speed. The fans total only 7 hp, and the hoods remove 10,200 cxfm of exhaust from the kitchen. As a smallmedium sized business in the emerging energy efficiency and renewable energy space, our goal is to grow sales 30% per year and become a national leader. Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers. This type of starter is for use with 3phase motors only. Melink intelli hood system controls exhaust fan cooking equipment interlock control sloped front design for low ceiling application ul listed exhaust volume damper available on all models with 2 exhaust collars ul listed electromechanical manual reset fire damper assembly with fail safe fusible link back up. A manual system would be a natural ventilation system you would use by hand, this can either be operated by a remote handle, an opener pole or a cord and the best choice depends on your specific application.
Updated staffing plans to support melink products and services. Both the accurex variflow air management system and the melink intelli hood system align with the following leed credits and may contribute toward earning up to two leed credits. Let us help you meet kitchen energy management goals. Greenheck fan ggh20, grease grabber h2o autocleaning hood. We are looking for a fulltime general manager to help take our company to the next level. While all work on the same basic principles, they do not have the same parts or interfaces. The mbdr50 is a round manual balancing damper regulating the flow of air in an hvac system. Greenheck is dedicated to full and complete compliance with all u. Melink intelli hood known as ecosense by ecocanopy is a demand ventilation product.
Taku premier ventilation exhaust only water wash canopy. Green building council are not interested in awarding credits for specific manufacturers products, but are interested in awarding credits for unique design approaches and. Purpose is to mainstream this superefficient technology. Use with honeywell flame safeguard primary safety controls and burners requiring ultraviolet flame detection. View and download greenheck fan ggh20 instruction manual online. Apr 24, 2015 a brighter tomorrow 2015 melink launches its 4th business in geothermal hvac pumping stations, financing, and commissioning. Melink corporation offers intelli hood, an hvac kitchen ventilation controls system that can be installed into any commercial hood system. Operations manual melink intellihood controls culinaire.
Melink intelli hood controls installation manual melink corporation 5 9657300. Solution the melink intelli hood controls package is a demand ventilation based energy management system for commercial. Installation of melink intelli hood dcv sensor lowers fan speed during low heat usage, saving up to 50% daily exhaust system energy use. Let the fans run at full speed for about 30 minutes to verify that the vfd does not trip out on overload. The melink system uses temperature sensors mounted in the exhaust duct and optical sensors that detect heat, steam, and smoke from stove operations. Melink intelli hood system controls exhaust fan cooking equipment interlock control ul listed exhaust volume damper available on all models with 2 exhaust collars ul listed electromechanical manual reset fire damper assembly with fail safe fusible link back up. Mbd10m model mbd10m balancing damper offers a single blade with a synthetic bearing. We have emailed you a verification link to to complete your registration. Melink pioneered demand control ventilation controls for commercial kitchen hoods over 23 years ago. Export laws and regulations relevant to the conduct of its business. The optic sensors provide additional control, especially in large cooking batteries containing steamers, kettles and other similar appliances that produce a lot of smoke or steam. F fault 1, 2, 3 or 4 identifies the hood number, i. The melink intelli hood controls are the only proven solution to this the temperature sensor monitors the exhaust air temperature in the duct.
H2 means hood 2 h1e 100% h or h temperature fault h sensor fault code relating to high temperature or open circuithigh resistance h sensor fault code relating to low temperature or low resistance. Melink s intelli hood controls modulate the speed of the exhaust and fan motors with variable frequency drives vfds. The melink system uses temperature sensors mounted in the exhaust duct and optical sensors that detect heat, steam, and smoke from. Hood technical manual or contact melink corporation or your intelli. Understanding and knowing how to troubleshoot your intelli hood vfd will make maintenance easier.
1261 702 671 1047 845 285 922 1465 48 592 739 671 104 1612 1493 1282 211 1358 1361 406 67 168 1059